Dell PowerEdge R810 User Manual

Page 41

Advertising
background image

About Your System

41

Alert! Node

Interleaving

disabled! Memory

configuration

does not support

Node

Interleaving.

The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system will
run but without node
interleaving.

Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information for
possible causes. For memory
configuration information,
see "General Memory
Module Installation
Guidelines" on page 100. If
the problem persists, see
"Troubleshooting System
Memory" on page 169.

Alert! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.

If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. See "Power Supplies"
on page 94.

Alert! Redundant

memory disabled!

Memory

configuration

does not support

redundant

memory.

Memory Mirroring was
enabled in the system setup
program, but the current
configuration does not
support redundant memory.
A memory module may be
faulty.

Check the memory modules
for failure. See
"Troubleshooting System
Memory" on page 169. Reset
the memory setting, if
appropriate. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 59.

Message

Causes

Corrective Actions

book.book Page 41 Thursday, February 18, 2010 2:06 PM