System Messages

System messages appear on the screen to notify you of a possible problem
with the system.

NOTE:

If you receive a system message not listed in the table, check the

documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.

Table 1-2.

System Messages

Message

Causes

Corrective Actions

Alert! iDRAC6 not

responding.

Rebooting.

The iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization. The
system will reboot.

Wait for the system to
reboot.

Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The iDRAC6 is hung.

The iDRAC6 was remotely
reset while the system was
booting.

After AC recovery, the
iDRAC6 takes longer than
normal to boot.

Remove AC power to the
system for 10 seconds and
restart the system.