Dell PowerEdge R810 User Manual

Page 52

Advertising
background image

52

About Your System

PCIe Training

Error: Expected

Link Width is x,

Actual Link Width

is y.

Faulty or improperly installed
PCIe card in the specified
slot.

Reseat the PCIe card in the
specified slot number. See
"Troubleshooting Expansion
Cards" on page 177. If the
problem persists, see
"Getting Help" on page 195.

Plug & Play

Configuration

Error

Error encountered in
initializing PCIe device;
faulty system board.

Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 177.

Read fault

Requested sector

not found

The operating system cannot
read from the hard drive,
optical drive, or USB device,
the system could not find a
particular sector on the disk,
or the requested sector is
defective.

Replace the optical medium,
USB medium or device.
Ensure that the SAS
backplane, USB, or SATA
cables are properly
connected. See
"Troubleshooting a USB
Device" on page 162,
"Troubleshooting an Optical
Drive" on page 173, or
"Troubleshooting a Hard
Drive" on page 174 for the
appropriate drive(s) installed
in your system.

SATA Portx device

not found

There is no device connected
to the specified SATA port.

Information only.

Message

Causes

Corrective Actions

book.book Page 52 Thursday, February 18, 2010 2:06 PM