Specifications, Multitest torque calibration system – CDI Torque MULTITEST Government User Manual

Page 27

Advertising
background image

2-11

Functional Description and Specifications

Specifications

MULTITEST Torque Calibration System

System Accuracy

±0.25% of reading @ 25°C

(Indicator and transducer calibrated together)

MULTITEST Transducers used with, but not calibrated

to, another MULTITEST Indicator provide a system

accuracy of ±0.5% of reading @ 25°C.

Temperature Drift

+0.03%/°C (+0.017%/°F)

Angle Precision

Bi-directional rotary encoder pulses/revolution X4

2000-610-02 Indicator

Display Accuracy

±0.05% of reading @ 25°C

Temperature

Operating Temperature
10 to 32°C (50 to 90°F)
Storage
-20 to 50°C (-2 to 122°F)
Humidity
Up to 90%, Non-condensing
Temperature Drift

+0.011%/°C, (+0.006%/°F)

Dimensions

Width

16.5"

Height

6.25"

Depth*

14.5"

*Includes handle, feet, printer and connectors

Weight

13.5 lbs

Power Supply

UL approved, 120VAC/220VAC, 50-60 Hz

Amperage, 3.15 amps

Advertising