3-2

Setup and Programming

Setting up the MULTITEST Torque Calibration System

1. Position the roll cabinet on a level floor and lock the

wheels.

2. Mount the indicator stand, part number 2000-111-0, to

the Loader.

3. Mount the MULTITEST 2000-610-02 Indicator to the

stand.

4. Connect the solenoid control cable between the Indicator

and Loader.

5. Install the appropriate MULTITEST transducer to the

Loader drive.

6. Install two (2) quick release pins, part number 2000-95-

13.

7. Connect the transducer cable, part number 2000-116,

between the Indicator and transducer.

8. Select the appropriate AC voltage input at the rear of the

Indicator and Loader. Connect the AC power cables to

the Indicator and the Loader. For additional information

refer to Chapter 6—Loader Rear Panel Controls.

9. Install the safety shield to the front of the Loader.

10. Install the reaction pins part number S/2000-173-1 and

S/2000-173-2 into the reaction slide on the Loader.

For testing procedures refer to Chapter 4—Using

the Torque Tester.

Various fixtures, cables and adaptors are available for testing

the most common compression or tension gauges.

11. Install two linear bearings, part number S/2000-173-11.

Advertising