Setting up serial communications – CDI Torque MULTITEST Government User Manual

Page 42

Advertising
background image

3-12

Setup and Programming

3. Press ENTER.

— The LED display reads:

PRINTER or PC

— The LCD display reads:

Download: - upper line

Port - lower line

4. Press up VALUE to toggle between "PRINTER" port or

optional “PC”.

5. Press ENTER to return to measurements mode.

Setting Up Serial Communications

1. Press CAL to enter calibration mode.

— LED display reads the following with the least

significant digit (LSD) flashing:

CODE0000

2. Use left and right DIGIT to select the appropriate digits

and up and down VALUE to increment or decrement

each digit between "0" and hexidecimal "F," program the

number "2000" into the LED display.

3. Press ENTER.

— The LED display reads:

PRINTER or PC

— The LCD display reads:

Download: - upper line

Port - lower line

4. Press right DIGIT.

— LED display shows the previously programmed baud

rate for the printer with the LSD flashing.

— LCD display reads:

Baudrate Com1

5. Using up and down VALUE and left and right DIGIT,

program the baud rate matching the printer being used.

The built-in printer operates at 09600 baud.

6. Press right DIGIT until LCD display reads:

Baudrate Com2

— LED display shows the previously programmed baud

rate for the optional PC port with the LSD flashing.

7. Using up and down VALUE and left and right program

the desired baud rate that matches the PC being used.

The recommended default is 09600 baud.

Advertising