ETS-Lindgren HI-4422 Field Probe (Archived) User Manual

Page 86

Advertising
background image

PENDING (amber)—Indicates the battery charger detects a battery.

Before fast charging can begin, the battery voltage must fall within

predetermined acceptable limits. A pulse-trickle charge is provided to

bring a depleted battery to a valid charge prior to fast charge.

CHARGING (amber)—Indicates the voltage pre-qualification condition

has been met, and fast charge has started.

Fast charging continues until termination by a peak voltage detect or a

maximum charge time. For peak voltage detect, the fast charge is

terminated when the battery voltage is lower than the previously

measured values by 24mV. If a peak voltage is not detected, then the

fast charge is terminated when the maximum time limit of 180 minutes

is reached.

COMPLETE (green)—Indicates a fast charging peak voltage is

detected.

If the probe is turned on during the fast charge period of the charge

cycle, the current surge that the batteries provide to the electronics in

the probe will cause a momentary voltage drop on the batteries,

causing the charger to terminate the fast charge based on a peak

voltage detect condition.

The battery charger switches to top-off charge mode that provides a charge

current one-eighth of the fast charge rate. This charge continues from the time

when a peak voltage detect terminates the fast charge, until the maximum time of

180 minutes is reached. If the probe is disconnected from the charger at this

point in the charge cycle, the batteries will operate properly.

Following the maximum time of 180 minutes, a pulse-trickle charge mode is used

to compensate for the self-discharge of the batteries while idle in the charger.

The fast charge current is low enough that there is not always enough heating of

the battery cells to cause the voltage to drop. With no voltage drop there is no

peak voltage detection, and the fast charge will terminate after the maximum time

of 180 minutes is reached.

86

|

Series H-491198-01 Battery Charger for NiMH Batteries

Archived 6/29/10