Appendix C: Series H-491198-48 Battery Charger

for NiMH Batteries

Appendix C: Series H-491198-48 Battery Charger

for NiMH Batteries

The HI-6022 and HI-6005 probes contain a Nickel-Metal Hydride

(NiMH) battery, and use the Series H-491198-48 Battery Charger.

S

AFETY

P

RECAUTIONS

Before operating the Series H-491198-48 Battery

Charger, see General Safety Considerations on

page ix.

I

NTRODUCTION

The H-491198-48 Nickel-Metal Hydride

(NiMH) Battery Charger is a dual power

source battery charger. It charges 4.8 volt

25 mA NiMH batteries and is powered by

85-264 VAC line power or 12.5 VDC. The

H-491198-48 Battery Charger uses a

-(dV)/(dT) negative delta V technique to

determine when the battery is fully charged,

which is typically two hours. With this

technique, the charge state of the battery

has no effect other than shortening the

charge time.

Housed in a rugged enclosure, power enters the battery charger through a power

entry module, which contains the fuses, or an optional cigarette lighter plug

adapter. The front face of the battery charger displays LEDs that provide the

operating status. The battery charger connects to the device being charged

through a short cord terminated with a power jack.

An integrated circuit within the battery charger monitors the battery voltage and

controls the charging functions according to the charge state of the battery.

Series H-491198-48 Battery Charger for NiMH Batteries

|

91