Kontron AT8050 User Manual

Page 36

Advertising
background image

20

AT8050

www.kontron.com

2.9.4.4

AMC to Fabric Interface and Management to Front Panel
Configuration

Figure 2-6: AMC to Fabric Interface and Management to Front Panel

Note:

- The AMC must be able to support GbE on ports 8-11
- Connection from AMC to the Fabric Interface is either PICMG3.1 option 2 (2x1GbE) or PICMG3.1
option 1 (1xGbE).

BIOS Settings:

1) System Management --> OEM E-Keying Configuration --> Management LAN Setting: Front
Panel
2) System Management --> OEM E-Keying Configuration --> AMC P8-11 Setting: Fabric Interface
In this configuration, it is not possible to boot from the Fabric Interface

MGNT

82576EB

Front
2x RJ-45

AMC

BI

82576EB

RTM

Ports 0-1

Ports 0-1

Fabric Interface

Channel 1

Ports 0-1

Base Interface

Channel 1

GbE

Fabric Interface

Channel 2

Ports 0-1

82599EB

10 GbE

Output 1

Output 2

Base Interface

Channel 2

Copper

Copper

1

2

AMC

AMC

Ports 9, 11

Ports 0-1

Ports 8, 10

Advertising