1 ipmc sensors, Table 4-17 ipmc sensors – Kontron AT8050 User Manual

Page 65

Advertising
background image

49

AT8050

www.kontron.com

4.3.2.1

IPMC Sensors

Table 4-17: IPMC Sensors

ID

Sensor Name

Sensor Class

Description (Sensor Type, Event trigger)

0

FRU0 Hot Swap

Discrete

ATCA Board FRU Hot Swap Sensor for FRU 0 (Front Board)

Sensor type code = F0h PICMG Hot Swap

Event Reading type code = 6Fh Sensor specific

See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”

1

FRU1 Hot Swap

Discrete

ATCA Board FRU Hot Swap Sensor for FRU 1 (AMC B1)

Sensor type code = F0h PICMG Hot Swap

Event Reading type code = 6Fh Sensor specific

See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”

2

FRU2 Hot Swap

Discrete

ATCA Board FRU Hot Swap Sensor for FRU 2 (RTM)

Sensor type code = F0h PICMG Hot Swap

Event Reading type code = 6Fh Sensor specific

See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”

3

FRU3 Hot Swap

Discrete

ATCA Board FRU Hot Swap Sensor for FRU 3 (RTM Disk)

Sensor type code = F0h PICMG Hot Swap

Event Reading type code = 6Fh Sensor specific

See PICMG 3.0 R3.0 Table 3-22, “FRU Hot Swap event message”

4

FRU0 Reconfig

Discrete

Sensor Population Change on Carrier

Sensor type = 12h System Event

Event Reading type code = 6Fh Sensor specific, only offset 0 is used -see AMC.0

R2.0 for event trigger

-see IPMI v1.5 table 36.3, Sensor type code 12h for sensor definition

5

Temp -48V A Feed

Threshold

DC Feed A Input Temperature (Degrees)

Sensor type = 01h temperature

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

6

Temp -48V B Feed

Threshold

DC Feed B Input Temperature (Degrees)

Sensor type = 01h temperature

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

7

Temp Mez 12V Out

Threshold

DC Feed 12V Out Temperature (Degrees)

Sensor type = 01h temperature

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

8

Temp VDDQ

Threshold

VDDQ Temperature (Degrees)

Sensor type = 01h temperature

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

9

Temp Vcore

Threshold

Vcore Switcher Temperature (Degrees)

Sensor type = 01h temperature

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

10

Temp IPMC

Threshold

H8S2472 IPM Controller Temperature (Degrees)

Sensor type = 01h temperature

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

11

Temp IOH

Threshold

I/O Hub (IOH) Chipset Temperature (Degrees)

Sensor type = 01h temperature

Event Reading type code = 01h threshold based

see IPMI v1.5 section 29.13.3 for threshold based event

Advertising