320IS Installation Manual - Introduction

5

To change a parameter value, scroll left or right to view the values for that parameter. When the desired value

appears on the display, press to select the value and move back up one level. To edit numerical values, use the

navigation keys to select the digit and to increment or decrement the value or use the numeric keypad (see

Figure 1-4).

Figure 1-4. Editing Procedure for Numeric Values

1.5

LED Annunciators

The

320IS

display uses a set of eight LED annunciators to provide additional information about the value being

displayed (see Figure 1-1 on page 3):

LED Annunciators

Gross

The Gross and Net annunciators are lit to show
whether the displayed weight is a gross or net
weight.

Net

Center of Zero

Gross weight is ±0.25 graduations of zero. This
annunciator lights when the scale is zeroed.

Standstill

Scale is at standstill or within the specified motion
band. Some operations, including tare functions and
printing, can only be done when the standstill symbol
is shown.

The Tare Acquired light shows that a tare value has
been entered.

Count

The Count annunciator is lit to show that the indicator
is in piece count mode.

Table 1-2. LED Annunciators

1

st

Level

Parameter

Default value

2

nd

Level

Parameter

Value

Value

1

st

Level

Parameter

2

nd

Level

Parameter

When moving thr ough values below the first menu level, press

to r etur n to the level

above. Pr

ess or

to move to the next parameter on the level above.

Value

When editing numeric values, press

or

to change th e

digit selected. Press

or

to incr ement or decrement the

value of t he selected digit, or use t he numeric keypad.

Pr ess

to save the value entered and return to the level above.

0 0 0 0 0 0