6 indicator operations, 1 toggle gross/net mode, 2 toggle units – Rice Lake Intrinsically Safe User Manual

Page 12: Toggle gross/net mode, Toggle units

Advertising
background image

6

320IS Installation Manual

Table 1-3 shows which annunciators are used for all combinations of configured primary and secondary units. For

example:

If the primary unit is pounds (lb) and the secondary unit is kilograms (kg), the

lb

LED is lit for primary

units,

kg

for secondary units.

If the primary unit is pounds (lb) and the secondary unit is short tons (tn), the

lb

LED is lit for primary

units,

kg

for secondary units. There is no LED for short tons, so the

kg

LED is used as the secondary units

annunciator.

If the primary unit is short tons (tn) and the secondary unit is pounds (lb), the

lb

LED is lit for primary units

(tn), and

kg

is lit for secondary units (lb). Because there is no LED for short tons, the

lb

and

kg

LEDs are

used as primary and secondary units annunciators.

See Section 3.3.2 on page 24 for more information about configuring primary and secondary display units.

1.6

Indicator Operations

Basic

320IS

operations are summarized below.

1.6.1

Toggle Gross/Net Mode

Press the

GROSS/NET

key to switch the display mode from gross to net, or from net to gross. If a tare value has been

entered or acquired, the net value is the gross weight minus the tare. The

Tare

(

) annunciator is lit when a tare

value is currently stored in memory.

1.6.2

Toggle Units

Press the

UNITS

key to switch between primary and secondary units. The appropriate units LED to the right of the

display is lit.

0 lb

lb and kg annunciators indicate the units associated
with the displayed value: lb=pounds, kg=kilograms.
Two units of measurement can be chosen to toggle
between.

The displayed units can also be set to ounces (oz),
short tons (tn), metric tons (t), grams (g), or they can
be disabled. A user-defined unit can also be set as
secondary unit by declaring a conversion factor in the
setup menu. The lb and kg LED’s function as primary
and secondary units annunciators for some
combinations of primary and secondary units. If
neither primary nor secondary units are lb, kg, oz, or
g, the lb annunciator is lit for primary units, kg for
secondary units.

0kg

Primary Unit

Secondary Unit

lb

kg

oz

tn

t

g

none

lb

lb / lb

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

kg

kg / lb

kg / kg

kg / lb

kg / lb

kg / lb

kg / lb

kg / lb

oz

kg / lb

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

tn

kg / lb

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

t

kg / lb

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

g

kg / lb

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

none

kg / lb

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

lb / kg

Table 1-3. Unit Annunciators, Primary/Secondary LEDs Used For All Configurations

LED Annunciators

Table 1-2. LED Annunciators

Advertising
This manual is related to the following products: