320IS Installation Manual - Appendix B

61

Use the following steps for assembling the fiber optics connectors of the

320IS

:

1. Cut off the ends of the fiber optic cable with a single-edge razor blade or sharp knife. Try to obtain a

precise 90º angle.

2. Insert the fiber through the locking nut and into the connector until the core tip seats against the internal

micro-lens.

3. Screw the connector locking nut down to a snug fit, locking the fiber in place.
4. Secure duplex fiber optic cable to wire tie mounting button located on I/O Module circuit board (see

Figure 8-1 on page 58) using wire ties included in parts kit.

Figure 8-4. Fiber Optics Connector

8.5

Analog Outputs

The

320IS

uses two 16-bit isolated analog output channels with 4-20mA and voltage (0-5V/±5V/0-10V/±10V)

outputs supplied from a DC/DC converter. The output voltage ranges are DIP-switch selectable (see Figure 8-1 on

page 58). Analog output configuration is done via setup mode in the indicator used with the

320IS

(see the

applicable indicator installation manual).
The analog output circuitry consists of two identical channels that can be assigned to gross or net weight values.

The analog outputs can be configured to operate as either current or voltage outputs. The voltage output range is

selected by configuring DIP switches SW1 (1-6) for channel 1 and SW2 (1-6) for channel 2 (see Figure 8-1 on

page 58).

The analog output port is powered by an isolated DC-DC converter. The outputs available on connector CN1 are

listed in Table 8-8 below. See Figure 8-1 on page 58 for the location of CN1 and DIP switches.

Range

SW1-1
SW2-1

SW1-2
SW2-2

SW1-3
SW2-3

SW1-4
SW2-4

SW1-5
SW2-5

SW1-6
SW2-6

0–5V

OFF

OFF

OFF

ON

X

X

0–10V

OFF

ON

X

OFF

ON

X

±5V

ON

OFF

OFF

OFF

ON

X

±10V

ON

OFF

ON

OFF

OFF

ON

Table 8-7. Analog Output Range Configurations

Pin

Name

1

Ground (Analog Output 1 Common)

2

Analog Output 1 (current)

3

Analog Output 1 (voltage)

4

Analog Output 2 (current)

5

Analog Output 2 (voltage)

6

Ground (Analog Output 2 Common)

Table 8-8. CN1 Connectors

Optical Fiber

Locking Nut

Portioning Foot

Housing

Lens

Mounting Hole

Device