5 normal mode commands, 2 saving and transferring data, 1 saving indicator data to a personal computer – Rice Lake IQ plus 2100SL Digital Bench Scale User Manual

Page 22: Normal mode commands, Saving indicator data to a personal computer

Advertising
background image

24

IQ plus 2100 Installation Manual

5.1.5

Normal Mode Commands

The serial transmit weight data commands (see Table 5-8) transmit data to the serial port on demand. The transmit

weight data commands are valid only in normal operating mode.

5.2

Saving and Transferring Data

Connecting a personal computer to the IQ plus 210

EDP port allo ws you to sa ve indicator configuratio

data to the PC or to do wnload configuration data fro

the PC to an indicator. The following sections describe

the procedures for these save and transfer operations.

5.2.1

Saving Indicator Data to a Personal Computer

Configuration data can be saved to a personal computer

connected to the EDP port. The PC must be running a

communications program such as PROCOMMPLUS

®

.

See Section 2.3.3 on page 5 for information about serial

communications wiring and EDP port pin assignments.
When configuring the indicato , ensure that the v alues

set for the BAUD and BITS parameters on the SERIAL

menu match the baud rate, bits, and parity settings

configured for the serial port on the PC
To save all configuration data, send the DUM

ALL

EDP command to the indicator . The IQ plus 210

responds by sending all configuration parameters to th

PC as ASCII-formatted text.

5.2.2

Downloading Configuration Data from PC to
Indicator

Configuration data saved on a PC or flop y disk can be

downloaded from the PC to an indicator

. This

procedure is useful when a number of indicators with

similar configurations are set up or when an indicator i

replaced.
To download configuration data, connect the PC to th

EDP port as described in Section

5.2.1. Place the

indicator in setup mode and use the PC

communications software to send the sa

ved

configuration data to the indicator . When transfer is

complete, calibrate the indicator as described in

Section 4.0 on page 20.

NOTES:

• Calibration settings are included in the

configuration data downloaded to the indicator .

If the receiving indicator is a direct replacement

for another IQ plus 210 and the attached scale is

not changed, recalibration is not required.

• When downloading configurations that includ

changed serial communications settings, edit the

data file to place the serial communication

changes at the end of the file. Communicatio

between the PC and indicator will be lost once

the indicator recei ves settings for baud rate

(BAUD parameter) or data bits and parity (BITS

parameter) that do not match those configure

for the PC.

Command

Description

Response Format

SX

Start serial streaming

OK or ??

EX

Stop serial streaming

OK or ??

RS

Reset system

XG

Transmit gross weight in displayed units

nnnnnn UU

where nnnnnn is the weight value, UU is the units.

XGL

Transmit gross weight in pounds

XGK

Transmit gross weight in kilograms

XGO

Transmit gross weight in ounces

XGG

Transmit gross weight in grams

XGC

Transmit gross weight in pounds and ounces

XE

Query system error conditions

nnnnn nnnnn

See Section 6.1.2 on page 25 for detailed information about
the XE command response format.