IQ plus 2100 Installation Manual

3.0

Configuration

To configure the IQ plus 210 indicator , the indicator

must be placed in setup mode. The setup switch is

accessed by removing the large fillister head scr w on

the enclosure backplate. Insert a scre wdriver into the

access hole and press the switch to enter setup mode.
When the indicator is placed in setup mode, the w ord

CONFIG

is shown on the display. The CONFIG menu is

the first of the main menus used to configure t

indicator. Detailed descriptions of these menus are

given in Section 3.2. When configuration is complete

press the setup switch ag ain to exit setup mode, then

replace the setup switch access screw.

3.1

Configuration Methods

The IQ plus 210 indicator can be configured by usin

the front panel b uttons to navigate through a series of

configuration menus or by sending commands or

configuration data to the EDP port. Configuration usin

the menus is described in Section 3.1.3.
Configuration using the EDP port can be accomplished

using either the EDP command set described in

Section 5.0 or Version 2.3 or later of the Re volution

configuration utilit .

3.1.1

Revolution Configuration

The Revolution configuration utility pr

vides the

preferred method for configuring the IQ plus 21

indicator. Revolution runs on a personal computer to set

configuration parameters for the indicator

. When

Revolution configuration is complete, configurati

data is downloaded to the indicator.

Figure 3-1. Sample Revolution Display

Revolution supports both uploading and do wnloading

of indicator configuration data. This capability allows

configuration data to be retrie ved from one indicator ,

edited, then downloaded to another.

To use Revolution, do the following:

1. Install Revolution on an IBM-compatible per-

sonal computer running Windows

®

3.11 or

Windows 95. Minimum system requirements

are 8MB of e xtended memory and at least

5MB of available hard disk space.

2. With both indicator and PC po

wered off,

connect the PC serial port to the RS-232 pins

on the indicator EDP port.

3. Power up the PC and the indicator . Use the

setup switch to place the indicator in setup

mode.

4. Start the Revolution program.

Figure 3-1 shows an example of one of the Re volution

configuration displays
Revolution provides online help for each of its

configuration displays. Parameter descriptions provided

in this manual for front panel configuration can also b

used when configuring the indicator using R volution:

the interface is different, but the parameters set are the

same.

3.1.2

EDP Command Configuration

The EDP command set can be used to configure the I

plus 210 indicator using a personal computer, terminal,

or remote keyboard. Like Revolution, EDP command

configuration sends commands to the indicator serial

port; unlike Revolution, EDP commands can be sent

using any external device capable of sending ASCII

characters over a serial connection.
EDP commands duplicate the functions available using

the indicator front panel and pro vide some functions

not otherwise available. EDP commands can be used to

simulate pressing front panel b uttons, to configure th

indicator, or to dump lists of parameter settings. See

Section 5.0 on page 22 for more information about

using the EDP command set.