26

IQ plus 2100 Installation Manual

6.6

Bench Scale Maintenance

This section pro vides instructions for replacing load

cell, adjusting lift-up and o verload protection screws,

and installing the optional clamshell enclosure. See

Section 6.7 on page 28 for additional dra wings and

information about RL2100 replacement parts.

6.6.1

Load Cell Replacement

Use the following procedure to replace the load cell in

RL2100 bench scales:

1. Disconnect power to the indicator.

Before opening the indicator enclosure,
ensure power to the indicator is
disconnected.

2. Disconnect the load cell cable at the indicator.
3. Lift off scale platter. Remove lift-up protection

screws from spider plate and base assembly.

4. Use 7/16" wrench to remo ve upper load cell

screws and lock washers. Remove spider plate

and upper load cell shim from load cell.

5. Turn scale o ver and unscre w overload

protection set screw one full turn.

6. Use 7/16" wrench to remo ve lower load cell

screws and lock w ashers. Remove the lo wer

load cell shim, load cell and cable.

7. Thread replacement load cell cable through

rubber grommet.

8. Position load cell on lo wer shim. Install lower

load cell lockwashers and screws. Torque to 80

in-lb (9.0 N-m).

9. Set scale on its feet. Position upper shim on

load cell, then install spider plate and lift-up

protection screws.

10. Install upper load cell lockwashers and screws.

Torque to 80 in-lb (9.0 N-m).

11. Replace scale platter. Ensure that scale is level.
12. Connect load cell cable to indicator (see

Table 6-1 on page 20).

13. Readjust lift-up protection scre

ws and

overload protection set scre w as described

under Section 6.6.2 on page 27.

14. Power-up indicator and recalibrate scale.

Figure 6-9. RL2100 Components (Side View)

Warning

Spider Plate

Platter

Load Cell

Bubble Level

Upper Shim

Lower Shim

Upper Load Cell
Screws

Lower Load Cell

Screws

Corner Overload

Protection Screw

(one in each corner)