4 specifications, 1 iq plus 210 indicator, 2 rl2100 bench scale – Rice Lake IQ plus 2100SL Digital Bench Scale User Manual

Page 38: Iq plus 210 indicator, Rl2100 bench scale, 1 iq plus 210 indicator power, Analog specifications, Digital specifications, Serial communications, Operator interface

Advertising
background image

Appendix

27

6.4

Specifications

6.4.1

IQ plus 210 Indicator

Power

Line Voltages

115 or 230 VAC

Frequency

50 or 60 Hz

Power Consumption

70 mA @ 115 VAC (8W)
35 mA @ 230 VAC (8W)

Fusing

115 VAC

2 x 200 mA TR5 subminiature fuses
Wickmann Time-Lag 19374 Series
UL Listed, CSA Certified

230 VAC

2 x 100 mA TR5 subminiature fuses
Wickmann Time-Lag 19372 Series
UL Recognized, VDE Approved

Analog Specifications

Full Scale Input Signal Up to 35 mV
Excitation Voltage

10 ± 0.25 VDC,
4 x 350Ω load cells

Analog Signal

Input Range

0.6 mV/V – 4.5 mV/V

Analog Signal

Sensitivity

0.3 µV/graduation minimum,
1.5 µV/grad recommended

Input Impedance

200 MΩ, typical

Display Resolution

10 000 dd

Input Sensitivity

155 nV per internal count

System Linearity

Within 0.01% of full scale

Calibration Method

Software, constants stored in

EEPROM

Common Mode

Voltage

–1.05 to +0.95 V, referred to earth

RFI Protection

Signal, excitation, and sense lines
protected by capacitor bypass

Digital Specifications

Digital Inputs

2 inputs, TTL or switch closure,
active-low

Digital Filter

Software selectable

Serial Communications

Serial Port

Full duplex RS-232; 9600, 4800,
2400, 1200 bps; 7 or 8 data bits;
even, odd, or no parity

Operator Interface

Display

6-digit LED display. 7-segment, .8 in
(20 mm) digits

LED annunciators

Negative value, center of zero, motion,
kg, g, lb, oz

Keypad

2 piezo switches

Environmental

Operating Temperature –10 to +40°C (legal);

–10 to +50°C (industrial)

Storage Temperature

–25 to +70°C

Humidity

0–95% relative humidity

Altitude

2000 m (6500 ft) maximum

Enclosure

Enclosure Dimensions 9.5 in x 6 in x 2.75 in

24 cm x 15 cm x 7 cm

Weight

6.1 lb (2.8 Kg)

Rating/Material

NEMA 4X/IP66, stainless steel

Approvals

NTEP

CoC Number

00-045

Accuracy Class

III/III L

UL

File Number

E151461

Measurement Canada Approved
Approval

AM-5374

Accuracy Class

III/III HD

6.4.2

RL2100 Bench Scale

Load Cells

RL1042 aluminum load cell (standard)
RL1380 stainless steel load cell (optional)
Rated Output

2.0 mV/V

Maximum Overload

150%

Cable

10 ft (3.1 m)

Output Impedance

350Ω, nominal

Operating Temperature –10 to +40°C (legal);

–10 to +50°C (industrial)

Storage Temperature

–25 to +70°C

Dimensions & Capacities

Base Dimension

Capacity

10 in x 10 in (254 mm x 254 mm)5 lb (2.5 Kg)

10 lb (5 Kg)
25 lb (10 Kg)

12 in x 12 in (305 mm x 305 mm)50 lb (25 Kg)

100 lb (50 Kg)

Approvals

NTEP

CoC Number

95-072A2

Accuracy Class

III

Measurement Canada Approved
Approval

AM-5082 Rev 1

N

A

T

IO

NA

L CONFE

R

E

N

C

E

O
N

W

E

I G

H

T S

A N D M

E

A

S

U

R

E

S

UL

C

US

LISTED

®

N

A

T

IO

NA

L CONFE

R

E

N

C

E

O
N

W

E

I G

H

T S

A N D M

E

A

S

U

R

E

S

Advertising
This manual is related to the following products: