3 front panel configuration, Front panel configuration, The menus is described in section 3.1.3 – Rice Lake IQ plus 2100SL Digital Bench Scale User Manual

Page 9: Zero/enter, Units/right

Advertising
background image

Configuration

11

3.1.3

Front Panel Configuration

The IQ plus 210 indicator can be configured using a series of menus accessed through the indicator front pane

when the indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.

Figure 3-2. Front Panel Key Functions in Setup Mode

Menu

Menu Function

CONFIG

Configuration

Configure grads, zero tracking, zero range, motion band, overload, and digital filtering
parameters.

FORMAT

Format

Set format of primary units, select alternate display units.

CALIBR

Calibration

Calibrate indicator. See Section 4.0 on page 20 for calibration procedures.

SERIAL

Serial

Configure serial port.

DIG IN

Digital Input

Assign digital input functions.

DEFLT

Default

Restore default configuration.

VERS

Version

Display installed software version number.

Table 3-1. IQ plus 210 Menu Summary

D I G I T A L W E I G H T I N D I C A T O R

ZERO/ENTER

Move down in menu or

enter parameter value and

return to menu level above

UNITS/RIGHT

Move right in menu /

next parameter value

kg

g

lb

oz

ZERO

UNITS

Zero

Motion

Neg