Appendix

25

6.0

Appendix

6.1

Error Messages

The IQ plus 210 indicator provides a number of error messages. When an error occurs, the message is shown on the

indicator LED display. Error conditions can also be checked remotely by using the XE EDP command as described

in Section 6.1.2.

6.1.1

Displayed Error Messages

The IQ plus 210 provides a number of front panel error

messages to assist in problem diagnosis. Table 6-1 lists

these messages and their meanings.

6.1.2

Using the XE EDP Command

The XE EDP command can be used to remotely query

the IQ plus 210 for the error conditions sho wn on the

front panel. The XE command returns tw o 5-digit

numbers in the format:

xxxxx yyyyy

where

xxxxx

contains a decimal representation of an y

existing error conditions as described in Table 6-2.
If more than one error condition e xists, the number

returned is the sum of the v alues representing the error

conditions. For example, if the XE command returns

the number 528, this v alue represents the sum of an

A/D physical error (512) and an

A/D calibration

checksum error (16).
The second number returned (

yyyyy

) uses the same bit

assignments as shown in Table 6-2 to indicate whether

the test for the error condition w as run. For example,

the value

yyyyy

= 51807 represents the decimal

equivalent of the binary v alue 1100 1110 0111 1111.

Using the bit assignments in T

able 6-2, this v alue

indicates all tests were run.

Error Message

Description

Solution

E A/D

A/D physical error

Call Rice Lake Weighing Systems (RLWS) Service.

EEEROM

EEPROM physical error

EVIREE

Virgin EEPROM

Use the DEFLT menu to restore defaults, then recalibrate load cells.

EPCKSM

Parameter checksum error

EACKSM

A/D calibration checksum error

A/D converter requires recalibration. Call RLWS Service.

ELCKSM

Load cell calibration checksum error

Recalibrate load cells.

EIDATA

Internal RAM checksum error

Call RLWS Service.

INOVFL

Internal overflow error

Remove weight from scale. If error recurs, check configuration, check
scale for damage.

OVERFL

Overflow error

Weight value too large to be displayed.

- - - - - -

Gross > overload limit

Gross value exceeds overload limit. Check configuration.

_ _ _ _ _ _

A/D underrange

A/D reading < –4 mV. Check scale for binding or damage.

Table 6-1. IQ plus 210 Error Messages

Error

Code

Description

Binary Value

0

No error

0000 0000 0000 0000

1

EEPROM physical error

0000 0000 0000 0001

2

Virgin EEPROM

0000 0000 0000 0010

4

Parameter checksum error

0000 0000 0000 0100

8

Load cell calibration
checksum error

0000 0000 0000 1000

16

A/D calibration checksum
error

0000 0000 0001 0000

32

not assigned

0000 0000 0010 0000

64

Internal RAM checksum error 0000 0000 0100 0000

128

not assigned

0000 0000 1000 0000

256

not assigned

0000 0001 0000 0000

512

A/D physical error

0000 0010 0000 0000

1024

not assigned

0000 0100 0000 0000

2048

Internal overflow error

0000 1000 0000 0000

4096

not assigned

0001 0000 0000 0000

8192

not assigned

0010 0000 0000 0000

16384 A/D underrange

0100 0000 0000 0000

32768 Gross > overload limit

1000 0000 0000 0000

Table 6-2. Error Codes Returned on XE Command