5.0

Weight Extraction

This section describes the

TicketPress

data input requirements and the resulting printed output format when the

Print Mode

is set to

Weight Extraction

. There are two modes available.

The information provided by the indictor is sent to the

TicketPress

as data “records” in one of two predefined

formats. The expected format is determined by the value of the

Toledo Mode

menu setting. Each format is

described below.

Required Printer settings:

Ticket out fault - OFF

Baud rate - 19.2k or below

XON/XOFF - OFF

Echo - OFF

Auto CR/LF and AUTO LF are defaulted to ON

5.1

Weight Extraction - Demand

Print button will control indicator I/O. (Indicator must have Print digital I/O input) I/O goes into active low.

1. Set indicator for Demand.

13

14

1

25

Wire Pin 11

Ground

Rec

2. Set Printer for Weight Extraction Demand.
3. CR/LF as last character in serial string.
4. Wire pin 3 & 7 for RS-232(see Wiring for other

options).

5.2

Weight Extraction - Echo

Function is used for continuous output to printer and remote display. Print button from printer functional (not
indicator).

Indicator Shear

Prints weight extraction demand and interface ECHO on wiring:

2 - Remote Display

3 - Indicator

7 - Remote display and Indicator

5.3

Data Input Record – Toledo Mode = No

Record Format:

<STX><POL><WWWWWWW><UNIT><G/N><S><TERM>

Where:

<STX> = ASCII STX (0x02)

<POL> = Polarity. SPACE (0x20) = Positive, “-” (0x2d) = Negative

<WWWWWWW> = Weight. 7 character string with digits right justified. No leading zeros except for

only one preceding decimal point.

<UNIT> = Unit of measure.

L = Pounds

K = Kilograms

T = Short tons

G = Grams

<SP> (0x20) = OZ, GN, T, LT, TROYOZ, TROYLB, NONE

<G/N> = Gross/Net. G = Gross, N = Net.

<S> = Status. <SPACE> (0x20) = Valid,

I = Invalid, M = Motion,

O = Over/under range

<TERM> = Record terminator. CRLF (0x0d0a), or CR (0x0d), or LF (0x0a)

Note

Software does not allow leading zeros to be spaces, spaces are not accepted in front of data.