28
TicketPress
Operator’s Manual
6.2
RS-422 Interface
When pre-installed at the factory, the default configuration for this interface is as follows. To modify these
settings, refer to “Interface Menu” on page 18.
Interface Menu Item Value
Interface
RS-422
Baud Rate
9600
Data Bits
8
Stop Bits
1
Parity
None
DTR
Power On/Off
XON/XOFF
Off
ETX/ACK
Off
RTS/CTS
Off
Auto CR
Off
Auto LF
Off
Echo
Off
13
14
1
25
Pin
Signal
1
4
5
9
10
11
13
14
18
19
20
Chassis ground
+ 5V (through 4700 Ω resistor)
CTS (RS-232 level)
+ In
– In
Print (Open collector output pulsed low
when Print is pressed on front panel)
Ground
+5V
+ Out
– Out
DTR (RS-232 level)
RS-422 Serial Interface Connector