3 20ma current loop interface – Rice Lake TicketPress - Installation and Operation Manual User Manual
Page 33
RS-422 And 20mA Current Loop Interfaces
29
6.3
20mA Current Loop Interface
When pre-installed at the factory, the default configuration for this interface is as follows. To modify these
settings, refer to the “Interface Menu” on page 18 .
Interface Menu Item
Value
Interface
Current Loop
Baud Rate
9600
Data Bits
8
Stop Bits
1
Parity
None
DTR
Power On/Off
XON/XOFF
Off
ETX/ACK
Off
RTS/CTS
Off
Auto CR
Off
Auto LF
Off
Echo
Off
13
14
1
25
Pin Signal
Cable Part # 130213
1 Chassis ground
4 + 5V (through 4700 Ω resistor)
5 CTS (RS-232 level)
7 Ground
9 + In
Green
10 – In
White
11 Print (Open collector output pulsed low
when Print is pressed on front panel)
Yellow
13 Ground
14 +5 V
18 + Out
19 – Out
20 DTR (RS-232 level)
24 + 9V (through 330 Ω resistor)
25 + 9V
20mA Current Loop Serial Interface Connector
13
14
1
25
10 + In
7 - Out
9 -14
Active 20mA Current Loop
13
14
1
25
13 - Out
19 + Out
24 - 18
5-4
Active 20mA Current Loop
Echo Output
13
14
1
25
10
9
Passive