Monitor menu – Curtis ENABLE 40 User Manual

Page 42

Advertising
background image

36

Curtis enAble

®

40-Series Manual,

Rev. B

6

6 — MONITOR MENU

MONITOR MENU

Through its Monitor menu, the 1311 programmer provides access to real-time
data during chair operation. The Monitor menu has six submenus, which follow
the Active Config parameter at the top of the menu:

MONITOR MENU

—Active Config

Handcontrol

—Seat

—Lights

—Motor Controller

—Motors & Brakes

—Battery

MONITOR MENU

DISPLAY

ITEM

RANGE

DESCRIPTION

Active Config

1–4

Configuration that is currently selected.

HANDCONTROLS • • •
Handcontrol SW Ver.

0 – 255

Version number of the handcontrol software.

Drive Command

-100 – +100 %

Requested normalized (to 100%) Y-axis

throttle request incorporating the deadbands.

Turn Command

-100 – +100 %

Requested normalized (to 100%) X-axis

throttle request incorporating the deadbands.

Speed Mode

1 – 9

Speed Mode setting.

Speed Command

0 – 100 %

Speed Limit value in effect.

Horn Button

On/Off

Status of the Horn button.

Mode Button

On/Off

Status of the Mode button.

Aux 1 Button

On/Off

Status of the Aux 1 button ( ).

Aux 2 Button

On/Off

Status of the Aux 2 button ( ).

Left Turn Button

On/Off

Status of the Left Turn button.

Right Turn Button

On/Off

Status of the Right Turn button.

Hazards Button

On/Off

Status of the Hazards button.

Running Lights Button

On/Off

Status of the Running Lights button.

Handcontrol Inhibit

On/Off

Status of the Handcontrol Inhibit input.

SEAT • • •
Actuator 1 Voltage -37.5 – +37.5 V

Voltage applied to Actuator Motor 1.

Actuator 2 Voltage -37.5 – +37.5 V

Voltage applied to Actuator Motor 2.

Actuator Current

-12.0 – +12.0 A

Current through the actuator motors.

Advertising