Curtis ENABLE 40 User Manual

Page 43

Advertising
background image

37

Curtis enAble

®

40-Series Manual,

Rev. B

6 — MONITOR MENU

MONITOR MENU,

cont’d

ITEM

DISPLAY RANGE

DESCRIPTION

LIGHTS • • •
Indicator Current

0–26.5 A

Current through the indicator lights.

Running Light Current 0–26.5 A

Current through the running lights.

MOTOR CONTROLLER • • •
M1 Bridge Temp

0 – 200 °C

Temperature of power section for drive motor 1.

M2 Bridge Temp

0 – 200 °C

Temperature of power section for drive motor 2.

Current Limit

0–90 A

Ultimate current limit of the powerbase,

taking into account boost mode, thermal

protection, etc.

Motor Thermal Cutback 0–100 %

Amount the current is being reduced due to

the motor thermal protection algorithm.

MFI Speed Limit

0–100 %

Lowest speed limit in effect for MFI 1–3.

MFI1 Active

On/Off

Status of Multi-Function Input 1.

MFI2 Active

On/Off

Status of Multi-Function Input 2.

MFI3 Active

On/Off

Status of Multi-Function Input 3.

MOTORS & BRAKES • • •
Motor Trim

-127 – +127

Status of the Auto-Trim function.

M1 Current

-90.0 – +90.0 A

Current in drive motor 1.

M2 Current

-90.0 – +90.0 A

Current in drive motor 2.

M1 Voltage

-27.5 – +27.5 V

Voltage at drive motor 1.

M2 Voltage

-27.5 – +27.5 V

Voltage at drive motor 2.

M1 PWM

-100 – +100 %

PWM applied to drive motor 1.

M2 PWM

-100 – +100 %

PWM applied to drive motor 1.

Brake

On/Off

Status of electromagnetic brake.

System Resistance

0–477

Estimated motor resistance in real time.

This value will fall between the programmed

System Resistance and Hot System

Resistance values.

Resistance Test

0–477

Resistance of the system as measured by

the powerbase at the M1 and M2 terminals.

This variable only displays an accurate

resistance reading when the Motor Test

Mode parameter (see page 35) is On.

BATTERY • • •
Battery Voltage

0–38.5 V

Voltage of the main battery.

BDI %

0–100 %

Battery state-of-charge as estimated by the

powerbase.

Advertising