DO: 做到以下

Match the electrical outlet to the plug provided on the Wine Guardian.

Provide dedicated circuit and wiring for the system.

Match the wiring and breaker size to the rated load as shown on the serial

匹配电源插座和酒卫提供的插头。

 提供专门的系统电路和接线。
 按标牌显示,接线匹配,额定负荷断路器匹配

plate and in this guide. See sample serial plate illustration on ollowi



DO NOT:
不做以下

DO NOT MODIFY THE PLUGS IN ANY WAY!

Do not use extension cords.

 请勿以任何方式修改插头!

不要使用延长线插座。

Electrical

240/1/50

Electric Heat Amps (Opt.)

4.4

Locked Rotor Amps

18.5

Humidifier Amps (opt.)

0.3

Compressor RLA

2.4

Crankcase Htr. Amps (opt.)

0.4

Condenser Fan Amps

0.7

Min. Circuit Amps (w/o opt.)

4.4

Evaporator Fan Amps

0.7

Refrigerant

R-134-A

Condensate Heater

N/A

System Charge

625 g

Total Unit Amps (w/o opt.)

3.8

Test Pressure

1896 k pa