Installing the Ductwork

Use ductwork to connect the unit to the supply and return outlets in the wine cellar. Use only insulated ductwork
to minimize cooling loses, prevent sweating, and to reduce noise.

Use ductwork on the condenser section to redirect or absorb sound, to bring in outside air to the unit inlet,
and/or to exhaust the hot air out of the ambient space

安装管道系统
用通风管道连接酒窖, 应该尽量使用带隔热绝缘的通风管道,以减少冷气流失,防止产生冷
凝水, 也减少噪音。
冷凝部分(段)使用风管可起定向消声作用,也可以把室外空气送到主机进风口,和/或 将
热气排出室内环境空间。

NOTE: Do not exce

ed

a total of 7.5 metres for each length of ductwork run.

注:

每条管道长度不要超过 7.5 米。

CAUTION

注意

RISK OF DAMAGE TO EQUIPMENT

Avoid crimping the flexible ducts. This chokes down the inside area and reduces the airflow

causing the unit to operate erratically.

Be sure all ducts and surface in contact with the airflow are insulated

and have a vapor barrier on the outside surface.

Uninsulated ducts and surfaces cause bare exposed metal surfaces to sweat,

further degradation of the insulation and a loss of equipment cooling capacity.

Model

Inlet

Outlet

Single

Double

WG40

200

200

200

150

WG75

250

200

250

150

WG100

250

250

250

200

WG175

300

300

300

300

Evaporator (cooling) Coil

Notes: 1. The above references izes are internal diameter in mm.
2. If a single supply is used out of the unit but then splits into two (2) ducts, the above size
recommended for double is used after the split.

Double

150

200
250

250
300

Condenser (heat rejection) Coil

Recommended Insulated Flexible ductwork Sizing Chart

Inlet (Return Air)

Outlet (supply air)

Single

200
250

150