Service manual only – Wine Guardian Ducted Wine Cellar Cooling Systems (WG175) - Manual User Manual

Page 50

Advertising
background image

46

Advanced Settings--高级设置

Advanced Settings -
Special access required.
Contact Wine Guardian
Service Department for
access code

需要特别秘密。联系酒卫服
务部索取进入秘密

Setting 8 设置 8

Press “Settings” button to advance to Setting 8.

按“模式”按钮,直至设定 8。

Press the up or down arrow buttons to adjust

number to the access code. Press “Mode” button
to continue onto setting 9 through 19

.

按向上或向下的箭头按钮来调整进入代码。按
“模式” “MODE”按钮继续到 9 至 19 设置

Compressor anti-short
cycling time
压缩机避免 短循环的时

Setting 9 设置 9

Press “Settings” button to advance to Setting 9.
按“模式”按钮,直至设定 9。

Press the “Up” or “Down” arrow buttons to adjust
to the desired time in one (1) minute increments.
Maximum is 10 minutes, minimum is 0 minutes.
按“向上”或“下移”箭头按钮调整所需的时
间,以每一分钟为单位。最大为 10 分钟,最

小值是 0 分钟。

Compressor anti-short cycling time is the amount of
allowable time between compressor stop and restart.
Rapid start/stop of compressors can cause premature
failure. Factory default is 5 minutes.

WINE GUARDIAN DOES NOT RECOMMEND
SETTINGS LOWER THAN FACTORY
DEFAULT.
酒卫厂方建议在设置时不要缩短低于出厂默认的
设置值。

Set up remote sensor or
thermostat
设置遥控传感器或温控

Setting 10 设置 10

Press “Settings” button to advance to Setting 10.

按“模式”按钮,直至设定 10。

Press the “Up” or “Down” arrow buttons to adjust
to the desired setting.

按“向上”或“下移”箭头按钮来调整所

需的设置

rS = Remote sensor rS =遥控传感器
rI = Remote interface rS=遥控接口
LI= Local interface – Through-the-wall unit only
LI=本地接口 – 只用于川墙式设备

A = Averaging – Jumper position within sensors
must be adjusted. See page 27.
A=平均 值- 传感器内的跳线位置必须调整。请
参阅第 27 页。