Warning, Brick loading – Steffes 6140 User Manual

Page 13

Advertising
background image

Step 7 Remove the sheet metal screws around the outer edge of the galvanized front panel. Remove the panel

and set it aside.

Step 8 Starting at the bottom, carefully lift each of the insulation blankets and drape them over the top of the

system.

Use face mask, gloves, and long sleeved garments when handling insulation materi-

als in compliance with generally accepted safety practices.

Step 9 Remove the front air channel by pulling out on the top of the air channel.

BRICK LOADING

Load the brick, one row at a time, using a left side, right side, center pat-

tern. Start at the back of the brick core and work forward. Make sure the

brick are placed so the grooved side is facing up, the notch is facing for-

ward, and the ridges are on the left and right (See Figure 4).
BRICK INSTALLATION TIPS:

•

Install bricks carefully to avoid damage to the insulation panels.

•

Remove loose brick debris to prevent uneven stacking of brick as

this can make installation of the elements and the brick core

temperature sensor difficult.

•

Brick rows MUST line up front to

back and side to side.

•

Half brick makes brick loading

easier by evening out the stacks.

Use the HALF BRICK (boxes

marked) in the proper rows and in

the correct positions as indicated in

Figure 4. The back half of the brick

MUST be installed in the back rows

and the front half (the notched brick

piece) MUST be installed in the

front rows.

Comfort Plus Commercial

Installation

n

3.04

Installation

Risk of fire. Can cause personal

injury or death. DO NOT operate

the Comfort Plus Commercial

system if damage to the insula-

tion panels on the inner sides of

the brick core occurs.

WARNING

BRICK LOADING

FIGURE 4

Load in row 6 and 12

HALF BRICK

FR

ON

T O

F U

NIT

NOTCH IN BRICK

Advertising