Important, Auxiliary load control, Humidifier/electronic filter installation – Steffes 6140 User Manual

Page 21: Installation

Advertising
background image

Comfort Plus Commercial

Installation

n

3.12

Installation

AUXILIARY LOAD CONTROL

The Comfort Plus Commercial System can be used to

provide control signals to other loads in the application. To

do so, connect low voltage control wires to the "COM" and

"NC" or the "COM" and "NO" positions of the low voltage

terminal block in the electrical compartment of the system.

(See Figure 17.) These contacts are rated for 30 volts, 3

amps maximum.

Maximum external load should not

exceed 60 VA on the system's class

II transformer.

IMPORTANT

TWO STAGE HEAT PUMP APPLICATION WITH VARIABLE SPEED BLOWER

FIGURE 16

TYPICAL AUXILIARY LOAD CONTROL

FIGURE 17

NOTE: During off-peak (charge) periods, the con-

tact is closed between "COM" and "NC".

W/

NO

NC

COM

Ou

td

oo

r

Ou

td

oo

r

C

R

H/E

Y2

Y1

AUX

O

G

RP

2

2

Y1 Y2

2

O

AP

P

Inputs

Peak

Aux.

Relay

Auxiliary Control Relay

Relay Contacts

Relay Coil

COM

NO/NC

COM

NO/NC

БВ

Б

В

Б

Г

ГВ

Д

ГВД

         

ЖЗИИЙ

И



БД





Е

!

"

#$

Б

Б

 

Б

!

Е$

$

     

  ! "" #$%&

    ' () 

 ( * 

  +) ,("

  ! , " () 

  ! , " ()  

    ' () 

Â

- 

* (.

 

"(

/0      + ("" 

IMPORTANT

è

HUMIDIFIER/ELECTRONIC FILTER INSTALLATION

The Comfort Plus Commercial system is capable of being connected to a humidifier and/or an electronic air

filter. If installing either of these devices, connections to the system are made to the bottom two relays on the

base I/O relay board inside the system's electrical panel. Refer to the Line Voltage Wiring Diagrams (Pages

A.03-A.04) for the location of these relays.
If installing a humidifier, connect it to the "HEAT CALL" relay. This relay closes during a heat call.
If installing an electronic air filter, connect it to the "FAN ON" relay. This relay closes during a fan call.

Thermostat

Stage

Thermostat

Output

Heat

Pump
Stage

% of

Selected

CFM

Heat Call

Status on

Digital Display

Discharge Air

Temperature

Target

1

Y1/G

1

50%

HC1

L048

2

Y1/Y2/G

2

100%

HC1

L048

3

Aux/Y1/Y2/G

2

100%

HC3

L049

Fan

G

0

400 cfm

HCF

N/A

Cool 1

Y1/G/O

1

50%

COOL

N/A

Cool 2

Y1/Y2/G/O

2

100%

COOL

N/A

Emergency

Heat

H/E

N/A

100%

HC3

L049

*Contractor Use Only

TWO STAGE HEAT PUMP