Appendix, C or higher for field connection of this device, A.04 comfort plus commercial – Steffes 6140 User Manual

Page 28: Supplied, Field

Advertising
background image

Appendix

Appendix

n

A.04

Comfort Plus Commercial

277V OR 347V SYSTEMS ONLY

WITH VARIABLE SPEED

Use copper or aluminum conductors rated for 75

o

C or higher for field connection of this device.

#5

#4

#1

Element

Element

#2

#7

Element

Element

#8

Element

Element

#10

Element

Element

#11

#13

Element

#14

Element

BLACK/YELLOW

WHITE

CORE

BLOWER

CORE

BLOWER

160 °

RED

N.C.

BLACK

BLUE

RESISTER

RESISTOR

BASE IO BOARD

DAMPER

BLACK

5 Amp

L2 240

L2 120

BLOWER

L1

1/4 Amp

TRANSFORMER

240v / 24v

SECONDARY

#6

Element

#3

#9

Element

Element

Element

#12

#15

Element

RELAY

RELAY

BLUE/WHITE

NO

COM

COM

NO

COM

NO

COM

NO

FAN ON

HEAT CALL

TRANSFORMER

SUPPLIED

TRANSFORMER

PRIMARY

BLUE

Secondary

120/240 VAC

Transformer

GROUND

BAR

NEUTRAL

LUG

FIELD

9 Pin Header

in the base of the

Connectors located

BLACK

BLACK

VARIABLE SPEED BLOWER

MANUAL RESET

BLUE/WHITE

190 °

160 °

N.C.

N.C.

BLU

E

/BLA

CK

BLUE

Heater & Plenum

BLUE/BLACK