Important, Low voltage electrical connections - peak control, Installation – Steffes 6140 User Manual

Page 18: Peak control terminal connections figure 13

Advertising
background image

208/240 SINGLE PHASE

CIRCUIT PHASING CONNECTIONS

FIGURE12A

Installation

n

3.09

Comfort Plus Commercial

Installation

The 60 AMP breakers are for internal

component protection only. Sizing of the

field wire and breaker size MUST be in

compliance with all applicable local,

state, and national codes and regulations.

Circuit Breakers

LIN

E

1

BLOWERS/CONTROLS CIRCUIT

LIN

E

2

LIN

E

1

LIN

E

2

LIN

E

1

LIN

E

2

LIN

E

1

LIN

E

1

LIN

E

2

To Serv

ice

(Break

er) Panel

CHARGE CIRCUIT #4

CHARGE CIRCUIT #3

LIN

E

2

CHARGE CIRCUIT #1

CHARGE CIRCUIT #2

277/480V AND

347/600V

THREE PHASE

FIGURE12B

SAMPLE SYSTEM IDENTIFICATION LABEL

FIGURE 11

6-Position Low Voltage Terminal Block Coding

RP = Peak Control Input Common

P = Peak Control Input

AP = Anticipated Peak (Pre-Peak) Control Input

COM = Peak Control Output Common

NC = Peak Control Output (Normally Closed)

NO = Peak Control Output (Normally Open)

LOW VOLTAGE ELECTRICAL CONNECTIONS - PEAK CONTROL

Steffes ETS heating equipment may be controlled by the Power Company via a

peak control signal. This signal can be sent to the equipment using a Steffes

Power Line Carrier control system, low voltage wiring, a Steffes Time Clock

Module, or line voltage control. In applications utilizing automatic charge control,

outdoor temperature information is required and can be received via an outdoor

sensor or power line carrier control system.
The Comfort Plus Commercial system is factory configured for low voltage

peak control and is set to charge when the utility peak control switch

closes. Refer to the Configuration Menu (Pages 3.13-3.14) for information

on configuring the system for the application.

LOW VOLTAGE (HARD WIRED) PEAK CONTROL
If using the low voltage peak control option, the Comfort Plus Commercial

is direct wired to the power company's peak control switch. Field connec-

tions from the peak control switch are made to the low voltage terminal

block through a low voltage knockout located on the left side of the electri-

cal panel.
Step 1 Route a low voltage circuit from the power

company’s load control or peak signaling device to

the six (6) position low voltage terminal block inside

the electrical compartment of the Comfort Plus

Commercial system through one of its low voltage

wire knockouts.

Step 2 Connect the field wiring to positions "RP" and "P" on

the six (6) position low voltage terminal block. (See Figure 13.)

To use the system to control other loads, refer to Auxiliary Load Control (Page 3.12).

Low voltage wires

MUST never enter any

line voltage enclosure.

IMPORTANT

PEAK CONTROL

TERMINAL CONNECTIONS

FIGURE 13

NC

P

RP

COM

AP

NO

To Dry Contact Peak

Control Switch

Advertising