Step 3 Lower the insulation blankets back into position,

one at a time. Carefully tuck the sides of the

insulation into the edges, corners, and around the

exposed portions of the heating elements to

ensure maximum efficiency.

Step 4 Reinstall the galvanized front panel and secure it

to the system using the screws that were origi-

nally removed. Slide the bottom of this panel

inside the lower lip of the brick cavity. The top

rests on the outside of the cavity.

Step 5 Remove the electrical panel cover and locate the

element screw kit.

Step 6 Carefully route wiring harnesses and connect

them to the heating elements, using screws

provided in the hardware package. Make con-

nections with screw heads up and threads

pointing down. Element screws should be tightened to 20 inch lbs. Refer to Element Installation (Figure

5) for proper positioning.

Step 7 The brick core temperature sensor must be installed prior to putting the painted front panel in place.

Installation

Installation

n

3.05

Comfort Plus Commercial Hydronic

BRICK CORE TEMPERATURE SENSOR INSTALLATION

Step 1 Remove the screws by the brick core temperature sensor holes in the

galvanized front panel.

Model 7120 has one brick core temperature sensor

and Models 7130 and 7140 each have an upper and a

lower brick core temperature sensor.

Step 2 Insert the brick core temperature sensors through the holes in the

galvanized front panel. Be sure the sensor(s) are connected to the

relay driver board (Figure 7) as shown below. The sensor must pass

through the blanket insulation and into the brick core. Holes have not

been predrilled through the insulation. Use the sensor(s) to aid in

making a passageway by rotating them side-to-side while gently pushing inward.

Step 3 Once the brick core sensor(s) are installed, put the screws back

into position in the galvanized front panel to hold the sensors in

position and to provide the electrical ground.

Step 4 Check the non-insulated element terminations to make sure they do

not come within 1/2" of any surface area on the system.

Step 5 Re-install painted front panel using previously removed screws.

Risk of improper operation.

Proper installation of the

brick core temperature

sensor is critical to the

operation of the heating

system. Read and follow

installation instructions

carefully.

CAUTION

AIR CHANNEL PLACEMENT

FIGURE 6

Electrical

Panel

Front Air

Channel

BRICK

CORE

SIDE VIEW

Outlet

Inlet

7120

7130

} Lower Core

7140

} Lower Core

} Middle Core

} Upper Core

} Lower Core

} Upper Core

FIGURE 7