Optional accessories, Single electrical feed kit, Primary loop kit – Steffes 7140 User Manual

Page 8: Static heat recovery unit

Advertising
background image

Optional Accessories

2

Optional Accessories

n

2.01

Comfort Plus Commercial Hydronic

SINGLE ELECTRICAL FEED KIT

The Steffes Comfort Plus Commercial systems have built-in circuit breakers. They are

factory configured to be field connected to multiple line voltage circuits. If single feed

to the element and blowers/control circuits is desired, the single feed kit is available to

allow the system to be powered with a one, larger line voltage circuit. Contact the

factory for ordering details.

When using single feed, the neutral conductor MUST be sized in

accordance with all applicable local, state, and national codes and

regulations.

PRIMARY LOOP KIT

The Comfort Plus Commercial Hydronic system requires a primary water loop which serves to regulate heat transfer

from the unit’s heat exchanger. To minimize installation time and costs for field design and engineering of this loop,

Steffes Corporation offers a primary loop kit. The kit contains the components generally installed with hydronic heat

systems.

Features:

w Includes a 5-gallon diaphragm type expansion tank, Grundfos brand pump

(circulator), air separator, air vent, pressure gauge, and pump connection

conduit and fittings.

w Contains the appropriate valves to bleed air from the system during filling along

with automatic purge during system operation and draining.

w Incorporates isolation flanges for quick and easy servicing of the primary loop

pump (circulator).

w Offers troubleshooting isolation between the heating system and secondary

zones.

STATIC HEAT RECOVERY UNIT

In applications using the Steffes Air Handler, the static heat recovery unit would not be used.

During operation of the Comfort Plus Commercial Hydronic system, some heat from the brick core storage will

radiate through its outer panels. If the system is located in an area with minimal heating requirements, such as a

utility room, the static heat recovery unit can maximize the system’s efficiency

by transferring this static heat to a more desirable location.
Features:

w Connects directly to the Comfort Plus Commercial Hydronic system to

interface with the internal controls of the system for automatic operation.

w Specifications:

•

Wattage: 130 WATTS

•

Motor: .1 HP, 60 HZ

•

Voltage: 208/240 VAC

•

Maximum Static Pressure: .15 inches Water Column

•

CFM @.15 SP: 130 CFM

If the area available to install the Comfort Plus Commercial Hydronic system is less than 100

square feet, Steffes Corporation recommends installing a low voltage cooling thermostat,

connected between R and G on the 12-position terminal block, to maintain a temperature less

than 85 degrees Fahrenheit.