Error Code

Description

06

Outdoor sensor temperature from the transmitting device (PLC system) is out of normal operating

range. Check the outdoor sensor attached to the transmitting device and the transmitter for proper

operation.

07

Main processor control board temperature sensor is out of normal operating range. Verify that

none of the clearances have been violated and inspect the condition of the processor control

board.

08

Currently not utilized.

09

Currently not utilized.

10

Outlet water temperature has exceeded the maximum standard operating temperature.

20

There is no communication occurring between the Base I/O board and the processor control

board. This can be caused by a defective board interface cable or an unresponsive Base I/O

board.

21

There is no communication occurring with the first relay expansion board. The board interface

cable may be defective or the first expansion board may be unresponsive.

22

There is no communication occurring with the second relay expansion board. The board interface

cable may be defective or the second expansion board may be unresponsive.

23

There is no communication occurring with the Steffes time clock module.

24

Temperature sensor offset/reference is out of range and indicates one of the sensors is shorted to

ground, the processor control board is out of calibration, or the blower/control circuit is connected

to an improper input voltage.

25

Power line carrier system is active; however, no good data has been received.

26

Insufficient main control board memory. Contact a qualified service technician.

27

Insufficient permanent memory. Contact a qualified service technician.

28

Permanent memory change has been made. Press the M button to accept. This error message

indicates a change has been made to the software program; therefore, it is important to verify that

all location settings are correct for the application.

29

On-board communication system is not fully operable. Contact a qualified service technician.

30

Base I/O control board is in test mode. Check the jumper configuration.

31

Relay expansion board(s) are in test mode. Check the jumper configuration.

39

Indicates the value in Location 13 (L013) has been set to a value greater than the value in Loca-

tion 12 (L012). The system will not charge until the value in L013 is set lower than L012.

40

Press and release the M button to clear the error. If the error code reappears, contact a qualified

service technician.

41-44

Contact a qualified service technician.

Cold Core

Temperature of the brick core is below 40 degrees or the core sensing thermocouple may be

open.

Core Fail

Core high limit switch may be open.

PLC Fail

The system is configured for power line carrier control; however, is not receiving a valid power

line carrier communication signal.

LoAd CAP

All controllable loads have been shed and Maximum Load Capacity is still exceeded.