Figure 8-8, l, He- 111 − corrective maintenance, Figure 8-8. control box and recessed panel – AERCO SWDW68 U-Tube Double-Wall Heaters w/ECS User Manual

Page 72

Advertising
background image

HE-

111 − CORRECTIVE MAINTENANCE

Rev B Mar 2013

8-18

TEMP CONTROLLER

HOLD

RUN

AUTO

MAN

2408

PT.NO.

OVER TEMP SWITCH

PANEL
DOOR

CAPTIVE
SCREW

Figure 8-8. Control Box and Recessed Panel

2. Swing down the recessed panel and locate Terminal Block TB-2 (Figure 8-9).

REAR

TB-2

LINE

NEUTRAL

GROUND

100

101

102

GND

FRONT

VOLTAGE

REGULATOR

TERMINAL

BLOCK TB-2

EXTERNAL POWER WIRING

(120 VAC)

Figure 8-9. Control Box Interior Bottom View Showing Power Connections

3. Disconnect the Line, Neutral and Ground leads connected to Terminal Block TB-2.

4. Referring to figures in previous chapters (identified below), disconnect the Control Box cables from

the following devices:

a. Figure 1-3: Disconnect the Actuator cable (terminated in a 3-pin Molex connector) from the

Control Valve Actuator.

b. Figure 2-1. Disconnect the outlet temperature dual sensor cables (terminated in 4-pin Molex

connectors) from the DHW outlet dual temperature sensor installed in the upper head

TM

PT.NO.

SET

F

AUTO

RUN

MAN

HOLD

OP 1

OP 2

SP2

REM

2408

OVER TEMP SWITCH

TEMP CONTROLLER

PT.NO.

PANEL CAPTIVE

SCREW

OVER-

TEMPERATURE

SWITCH

RECESSED

PANEL