Compaq GS320 User Manual

Page 254

Advertising
background image

B-12

SMC Installation and User’s Guide

B.6

Cable the Terminal Server to the GS160/320

For each console, connect a terminal server port to the local port of
the PCI box.

B.6.1

Make the Cable Connection

Figure B–9 PCI Box Rear — Local Port Location

PK-1724-00

1

Make the connection for each console:

1.

Attach an H8585–AA connector (12–36054–01) to the local port of the PCI
box (

in Figure B–9).

2.

Following the cabling chart in Table B–1, label both ends of a BN25G cable
(17–03212–05) and connect it from the port on the terminal server (

in

Figure B–10 shows the location of the ports) to the H8585–AA connector on
the PCI box.

A partition can have a failover console if the limitation of eight standard I/O
modules in the system is met. The cabling chart in Table B–1 does not
distinguish between primary and failover consoles. For information about
partitioning the system, see the AlphaServer GS80/160/320 Firmware
Reference Manual
.