Compaq GS320 User Manual

Page 77

Advertising
background image

Configuring the SMC Software

5-25

1.

Keeping the GS80/160/320 keyswitch in the Off position, turn on the
breakers on the AC input boxes.

NOTE: Turning on the breakers applies power to the terminal server. These

instructions assume that the terminal server has not been powered
on until now. If it was on when you reached this point, power cycle
the terminal server now.

2.

Check the Access Server Loader window (Figure 5–18) for the following:

a.

The indicators on the BOOTP Server On/Off button and the TFTP
Server On/Off button should display green. If an indicator displays red,
click the button.

b.

The hardware address after Reply in the BOOTP Server block should
match the hardware address label on the terminal server. If it has been
at least one minute since you turned on the AC input box breakers and
the addresses do not match, do the following:

1.

Check that the terminal server has power (Section B.4 or C.4).

2.

Check that the cable from the terminal server to the SMC system is
connected correctly (Section 3.4).

3.

Check that the position identifier dial on the terminal server is set
correctly (Section B.3 or C.3).

If, after performing these three checks, you find that the Request
address is still different from the hardware address on the terminal
server label, refer to the terminal server documentation.

3.

Click the Close button to close Access Server Loader.

4.

Verify the connection.

a.

Open a Command window: From the Start menu select
Programs|Command Prompt.

b.

At the prompt, type

ping 90.0.0.1

. The response should be similar to

Figure 5–19.

c.

Close the Command window.

Advertising