Page 21: Use nwccon to configure ports as needed, Edit the autoexec.ncf file to add the load aiov, Power off the vs1000 to which the vs1100 will b, Connect the vs1100 to the vs1000, following the, Switch the vs1000 back on, Find the line in autoexec.ncf that initializes, Change the nports command in the load aiovs1 st

Advertising
background image

NetWare Connect Installation and Configuration

21

Novell NetWare

Adding VS1000 Virtual Servers

To add VS1000 virtual servers to an existing and operating Novell
NetWare Connect system, follow these steps:

1.

Connect the VS1000 unit to the Ethernet hub.

2.

Switch the VS1000 on, and verify that it passes power-up
diagnostics.

3.

At the system console, enter the load aiovs1 command for this unit,
using the syntax described in the AIOVS1.NLM Parameters table.

4.

Use nwccon to configure ports as needed.

5.

Edit the autoexec.ncf file to add the load aiovs1 command for the
new VS1000.

You are now ready to resume normal operations.

Adding VS1100 Expansion Units

To add VS1100 expansion units to an existing and operating NetWare
Connect system, follow these steps:

1.

Power off the VS1000 to which the VS1100 will be connected.

2.

Connect the VS1100 to the VS1000, following the instructions in
the Installing the Hardware section. Remember to put the
terminator plug in the OUTPUT connection on the last VS1100 in
the chain.

3.

Switch the VS1000 back on.

4.

Find the line in autoexec.ncf that initializes the host VS1000.

5.

Change the nports command in the load aiovs1 statement to reflect
the added ports.

6.

Down and restart the server so that your changes take effect.

7.

Use nwccon to configure the ports on the new unit as needed.

You are now ready to resume normal operations.