Socketserver – Comtrol DM AIR User Manual

Page 42

Advertising
background image

42 - DeviceMaster AIR User Guide: 2000365 Rev. C

Updating Firmware

SocketServer

SocketServer

Use this procedure to upload SocketServer.

1.

Select the Query button. If you have an NS-Link
driver running, it will display the NS-Link
version.

Note: If you did not close the application after

updating the Bootloader, the application
will respond with the Bootloader version. If
this occurs, close the application and
restart it.

2.

Select Ok after you confirm that it is the
DeviceMaster AIR that you want to update.

Note: If it is not the correct DeviceMaster

AIR, enter correct IP address and
repeat Step 1.

3.

Browse to the location of the .bin file for SocketServer.

4.

Select the Download button to start the update procedure.

5.

Select the Close button after the download has completed.

6.

Verify the new SocketServer version:

a.

Select the Reset button.

Note: There will be no screen change. If the DeviceMaster AIR is local,

watch the Ethernet LEDs to confirm that the DeviceMaster AIR did
reset.

b.

After the DeviceMaster AIR loads, select the Query button and confirm
that version numbers did change.

Advertising