Windows 2000, Troubleshooting checklist – Comtrol DM AIR User Manual

Page 66

Advertising
background image

66 - DeviceMaster AIR User Guide: 2000365 Rev. C

Troubleshooting and Technical Support

Windows 2000

Windows 2000

Use the following procedure if you need to assign a static IP address so that your
computer can communicate with the DeviceMaster AIR during the configuration
process.

1.

From the Start button, select Settings, Control Panel, Network and Dial-up
Connections
, and Local Area Connections.

2.

Select the Properties button.

3.

Select Use the following IP address, enter a temporary IP address and subnet
mask value that allows this system to communicate to the DeviceMaster AIR.

The default wireless IP address for the DeviceMaster AIR is 192.168.0.30. The
IP addresses on your network must be within the same range. For example,
you could enter an IP address of 192.168.0.3.

The subnet mask must be the same for all the computers on the network, for
example, 255.255.255.0.

A default gateway is not required.

Note: You may want to note the original IP information to return the PC to it’s

original IP configuration.

4.

Select Ok on the TCP/IP Properties page, select Close on the Local Area
Connections Properties page, and close the control panel.

If necessary, you can use this procedure to return your system to it’s original IP
configuration.

Troubleshooting Checklist

The following checklist may help you diagnose your problem:

Verify that you are using the correct types of cables on the correct connectors
and that all cables are connected securely.

Note: Most customer problems reported to Comtrol Technical Support are

eventually traced to cabling or network problems.

Isolate the unit from the network by connecting the device directly to a NIC in
a host system.

Verify that the Ethernet hub and any other network devices between the
system and the Comtrol device are powered up and operating.