Interlogix Concord Express User Manual User Manual

Page 40

Advertising
background image

34

Concord Express User Instructions

minutes remain to the Test Mode time, the system sounds a short beep every
60 seconds.

2. Use the procedures listed in Table 1 to test the individual sensors.

3. If you need more time to complete testing, restart the timer by pressing 8 +

Code + 3.

4. Check to see that all sensors have been tested by pressing *. Touchpads

display a list of untested sensors.

5. You will know that you have finished testing when touchpads display,

“SENSOR TEST OK” or “ZONES ALL TESTED.”

6. Disarm to Level 1 to exit Test Mode.

Phone Communication Test

The purpose of this weekly test is to verify that the connection between the
central monitoring station and your system is working properly.

Most phone tests take only a few minutes, however, your system will try for up to
15 minutes to establish a connection.

After the test has started, the arming level can be changed to Level 2—Stay or
Level 3—AWAY.

To perform a phone communication test:

1. Contact the central monitoring station to inform them that you want to test the

phone communication of your system.

2. Disarm the system.

3. Press 8 + System Master Code + 2. The touchpad displays, “System Armed

to PHONE TEST,” or “]PHONE TEST.”

On fixed display touchpads:

After the phone test is complete, the touchpad displays “PHONE TEST OK.”
Press *.

• If the phone test is successful, the touchpad displays “System Phone Test

Alarm Memory” or “Phone Test Memory” briefly, then returns to a normal text
display. Press * a second time and the touchpad displays “System is OK.”

• If the phone test is unsuccessful, the touchpad displays “Memory Test Phone”

briefly, then “Alarm Memory Phone Failure.”

On alphanumeric touchpads:

• If the phone test is successful, the touchpad display returns to a normal text

display.

Advertising