Setting the dome camera communication protocol – Interlogix TruVision PTZ Mini 12X User Manual User Manual

Page 14

Advertising
background image

1BChapter 2: Installation

10

TruVision Mini PTZ 12X Camera User Manual

Setting the dome camera communication

protocol

The TruVision Mini PTZ 12X Camera can use several different protocols for
communication. To select a protocol, you must set the protocol DIP switches to the
correct sequence of 1s (on) and 0s (off).
To set a dome camera protocol using the DIP switches
1. Locate the protocol DIP switch block (A, Figure 3 on page 9).
2. Using Table 3 below, find the DIP switch sequence for the desired protocol and set

the switches accordingly.

Table 3: Protocols supported

Protocol

Baud rate

Switch position

GE Impac RS-485

9600

000000

GE Digiplex RS-422

4800

100000

Pelco D

2400

010000

Pelco D

4800

110000

Pelco D

9600

001000

Pelco P

2400

101000

Pelco P

4800

011000

Pelco P

9600

111000

Advertising