Power cable size and length requirements

Using the proper gauge of power cable will ensure proper operation and avoid
voltage drops. See Table 2 below for the recommended cable gauge for varying
maximum cable lengths and power draws.

Table 2: Recommended power cable gauges based on maximum lengths for an operating voltage
of 24 VAC (±10%)

Wire gauge

Indoor dome cameras (14 W)

Outdoor dome cameras (54 W)

AWG mm

(diameter)

feet meters feet meters

10 2.59 2061 628 534 163

12 2.05 1294 394 335 102

14 1.63 813 247 211 64

16 1.29 512 156 133 41

18 1.02

322 98 83 25

20 0.81

203 62 53 16

22 0.64

127 39 33 10