Alarm settings, S 43 – Interlogix TruVision PTZ Mini 12X User Manual User Manual

Page 47

Advertising
background image

4BChapter 5: Advanced setup

TruVision Mini PTZ 12X Camera User Manual

43

Table 23: Day/night menu description

Function Description

Auto

Select this option for day/night mode to be automatically activated. The
internal circuit will automatically decide the threshold to remove the IR
cut filter according to the value of light condition calculated by internal
light algorithms. The options include Low, Mid, and Hi.

Low indicates a higher sensitivity and can improve reliability of lens so
that it is fast to switch to Day mode and relatively difficult to change into
Night mode; Hi indicates that it is fast to switch to Night mode and
difficult to change into Day mode.

This is the default setting.

Manual

Select manually whether day or night mode is activated.

Select On to deactivate the IR cut filter and put the camera in B/W (Night)
mode. Select Off to activate the IR cut filter and put the camera in color
(Day) mode.

Exit

Select Yes to save any changes and return to Main Page 3.

Alarm settings

You can program actions for alarms. The camera has eight alarm inputs and one
alarm output (NO and NC) to which to connect alarm devices.

Figure 23: Alarm setting menu

Table 24: Alarm setting menu description

Function Description

Alarm

Enable or disable this option. The default setting is Off.

Alarm Contact

Select a number for the alarm contact being setup. For alarm
contact definitions, please refer to “22-pin connector description”
on page 14.
Up to eight alarm contacts can be set.

Note: If two or more alarm contacts are triggered at the same
time, the lower alarm contact number will have priority. For
example, if Alarm 1 and Alarm 3 are triggered simultaneously,
only Alarm 1 will be handled.

Contact Type

Select the contact type (NO, NC).

Advertising