Interlogix TruVision Intelligent IP Dome Configuration Manual User Manual

Page 40

Advertising
background image

38

TruVision 12/32 Series IP Camera Configuration Manual

Figure 14: Audio exception detection window

To define audio exception detection:

1. From the menu toolbar, click

Configuration

>

Events

>

Audio Exception

Detection

.

2. Under

Audio Input Exception

, check Enable to activate the function.

3. Under

Sudden Change of Sound Intensity

check Enable to activate the function.

4. Configure the sensitivity and threshold.

Sensitivity: The smaller the value, the larger the change should be to trigger the
detection. The range is between 1 and 100.

Sound Intensity Threshold: This option filters the sound in the environment. The
louder the environmental sound, the higher the value. Adjust it according to the
actual environment. The range is between 1 and 100.

5. Click

Edit

to set the arming schedule for the alarm input. See “Motion detection

alarms” on page 26 for more information.

6. Specify the linkage method when an event occurs. Check one or more response

methods for the system when an audio exception alarm is triggered.

Advertising