Securing the rack cr-412-6 to the floor – Toa FS-970 SERIES User Manual

Page 13

Advertising
background image

13

6.5. Securing the Rack CR-412-6 to the Floor

Four anchor bolt mounting holes (ø15 mm) are provided in the rack bottom surface to secure the rack to the
floor. Referring to the figure below, make holes in the floor, then secure the rack to the floor using four M10-
M12 anchor bolts.

Front

460

400

615

(115)

100

360

440

566

Anchor bolt mounting hole (ø15 mm, 4 places)

Cable entry opening

6.6. Securing the Rack to the Wall (for Prevention of the Fall)

A knock-out hole (ø6.5 mm) is provided on the rack top panel. Break this hole with a screwdriver, and secure
the rack to the wall by installing a bracket in the exposed hole. (Note the bracket is not supplied with the
system. Purchase it separately in the market.)

Washer

Knock-out hole

Nut

Bracket

M6 bolt

Anchor

Bolt

[Installation example]

Advertising