9.6. DC Power Supply Panel Connection

9.6.1. When the DC power supply panel is not required (i.e. when you can do with the junction panel's

internal power supply)....

The power capacity of the Junction Panel's (JP-0410) internal power supply is 2 A in maximum output current.
Note the total current of connected components and external equipment. If their total current exceeds 2 A, the
power supply must be expanded. If not exceeding 2 A, use the junction panel with a jumper wire connected
between 24V IN and OUT terminals. (The jumper wire is connected at the factory.)

JP-0410's rear-mounted
terminal block

Jumper wire

Jumper wire

Rack mounted components

(Operation on 24 VDC)

Emergency power supply

DS-029B

OUT

IN

Internal circuit

Internal power supply

JP-0410

Emergency remote control unit

General remote control unit

Emergency cutoff 24 V

External equipment

Rack-mounted components (operation on 24 VDC)

Rack-connected external equipment (operation on 24 VDC)

Current Consumption

0.45 A

0.4 A

0.65 A

0.6 A

0.1 A

0.18 A

0.2 A

0.4 A

Model No.

JP-0410 (internal circuit)

JP-039-10

JP-039-20

EP-0510

EP-029-10

EP-029-20

PP-025B

MP-011

Component Name

Junction Panel

10-zone Expansion Junction Panel

20-zone Expansion Junction Panel

Integrated Control Panel

10-zone Expansion Operation Panel

20-zone Expansion Operation Panel

Pre-amplifier Panel

Monitor Panel

Current Consumption

0.3 A

0.1 A

0.18 A

0.13 A

0.13 A

Model No.

EP-059R

EP-029-10

EP-029-20

RM-1100

RM-1200

Component Name

Integrated Emergency Remote Control Panel

10-zone Expansion Operation Panel

20-zone Expansion Operation Panel

10-zone Remote Microphone

20-zone Remote Microphone