9.6.2. When expanding the power supply for external equipment

Let us assume that one expansion power supply is added to the system solely to cover the shortage of power
to be supplied to external equipment as the result of connecting many external equipment or mounting many
components in the rack.

Note: Remove the jumper wire placed between the 24V IN and OUT terminals of the terminal block located on

the rear panel of the Junction Panel JP-0410.

Rack mounted components

(Operation on 24 VDC)

DS-029B

OUT

IN

Internal circuit

Internal power supply

Emergency power supply

Expansion power supply

JP-0410

Emergency remote control unit

General remote control unit

Emergency cutoff 24 V

External equipment

<DC power supply panel>

Two types of expansion power supplies (DC power supply panels) are made available depending on the
current capacity.

GND

GND

GND

DC24V

DC24V

Main power supply

IN

OUT MAX10A

AD-031B's rear-mounted
terminal block

AD-011's rear-mounted terminal block

24 VDC OUT 24 VDC IN

AD-011: Maximum current 2.5 A

AD-031B: Maximum current 10 A

Connects to GND terminal of JP-0410's rear-mounted
terminal block.

Connects to DC24 V IN terminal of JP-0410's rear-
mounted terminal block.

Connects to DC24V IN terminal of JP-0410's rear-
mounted terminal block.

Connects to GND terminal of JP-0410's rear-mounted
terminal block.

9.6.3. When expanding the power supply for internal equipment

When many components are mounted in the rack, the power supply system needs to be divided using an
expansion power supply.

Memo
• Leave a jumper wire connected between 24V IN and OUT terminals of the terminal block located on the rear

panel of the Junction Panel JP-0410.

• Supply power to the Integrated Control Panel EP-0510 from the JP-0410.
• Connect the output terminal of the Emergency Power Supply Panel DS-029B to the DC input terminal of the

expansion power supply.

Rack mounted components

(Operation on 24 VDC)

Rack mounted

components

(Operation

on 24 VDC)

DS-029B

OUT

IN

Internal circuit

Internal power supply

Emergency

power supply

Expansion

power supply

JP-0410

Emergency remote control unit

General remote control unit

Emergency cutoff 24V

<DC power supply panel>

External equipment

Advertising