220 VAC, 50/60 Hz

95 W (120 VA)

10 lines each of R (Attenuator-free), N (Normal), and C (Common),

M3.5 screw terminal

(Maximum connectable wattage per line: 140 W for 70 V line, and 200 W for 100 V line)

ø5 mm miniature tubed fuse 0.5 A x 10 preinstalled (must be replaced depending

on the connected load capacity)

EL (automatic fire alarm system) 1-10, EF (automatic fire alarm system), and EC,

M3.5 screw terminal

(Open voltage: 24 VDC, Short-circuit current: 200 mA for both EL and EF)

Emergency RM audio inputs 1-4, 0 dBV, 600

Ω, M3.5 screw

Emergency RM power supply 1 and 2: 24 VDC (total current of both terminals 1 and 2: 5 A),

M3.5 screw terminal

Monitor output:

0 dBV, 600

Ω, M3.5 screw terminal

Emergency RM BUS1-4: RS-485, 9,600 bps, M3.5 screw terminal

Emergency start input:

M3.5 screw terminal

CPU off input:

M3.5 screw terminal

Battery 1 and 2 inputs:

M3.5 screw terminal

Check SW input:

M3.5 screw terminal

General RM power supply: 24 VDC, 0.5 A, M3.5 screw terminal

General RM BUS:

RS-485, 9,600 bps, M3.5 screw terminal

(RM-1200)

AUX control inputs 1-15:

Open voltage: 24 VDC, short circuit current: 5 mA,

M3.5 screw terminal

(RM-1100)

Chime start input:

Open voltage: 24 VDC, short-circuit current: 5 mA,

M3.5 screw terminal

Output during broadcast:

Open collector output, rated voltage: 30 VDC,

current capacity: 0. 1A, M3.5 screw terminal

Output during operation of remote control unit:

Open collector output, rated voltage: 30 VDC,

current capacity: 0.1 A, M3.5 screw terminal

24 VDC

180 mA [100 mA]

20 zones [10 zones]

Black

482 (w) x 88.4 (h) x 71.8 (d) mm

1.6 kg [1.5 kg]

EP-EP control connector cable x 1, EP-EP power supply connector cable x 1,

fuse (2A) x 1, rack mounting screw x 4, name label x 2

50

• 20-Zone Expansion Operation Panel EP-029-20

([ ] = 10-Zone Expansion Operation Panel EP-029-10.)

Power Source

Current Consumption

Output Control

Finish

Dimensions

Weight

Accessories

• Junction Panel JP-0410 (H version)

Power Source

Power Consumption

Speaker Line

Line Short Protection

Automatic Fire Alarm

System Input

Emergency Remote

Control Unit

Input

Output

Control

General Remote

Control Unit

Output

Control

Advertising