Power Consumption

303 W

572 W

700 W

33

9.5.2. Connecting the AC power supply of the Junction Panel JP-0410

• The Junction Panel JP-0410 supplies the AC power to each component mounted in the rack.
• AC power is always supplied to the UNSWITCHED AC outlets. Be sure to connect the Emergency Power

Supply Panel to the UNSWITCHED outlet to keep its internal batteries fully charged. Make sure that the DC
Power Supply Panels AD-011 and AD-031B are also connected to the UNSWITCHED outlet.

• AC power is supplied to the SWITCHED AC outlets when the pre-amplifier's power switch is set to the ON

position or when the broadcast zone is selected from any connected component or when the Emergency
Activation terminal is shorted. Power amplifier panels are mainly connected to the SWITCHED outlets.

Note: The "H" version is equipped with terminal blocks instead of the AC outlets.

Note: Up to a total of 450 VA for six UNSWITCHED AC outlets
(five on the rear panel and one on the front panel).

Up to a total of 450 VA for all two outlets

JP-0410's (L version) rear panel

JP-0410's (H version) rear panel

• Power consumption of the power amplifier panel
The following table shows the power consumption of each power amplifier panel, providing guidelines on the
maximum connectable power for the SWITCHED AC outlets.

Model No.

PA-1230B

PA-2440B

PA-3640B

Component Name

120 W power amplifier panel

240 W power amplifier panel

360 W power amplifier panel